Online seminars are screencasts and instructional videos where you watch and follow along with the relay testing expert as he performs a task.

Showing all 3 results

  • Fundamentals #2: How to Test Overcurrent Relays: An Introduction to Protective Relaying (32 NETA CTDs)

    Rated 5.00 out of 5
    $499.95 Add to cart

    This seminar covers the basics of overcurrent protection that new relay testers should know before they start testing relays. It will also fill in gaps for self-taught relay testers who had to figure it out for themselves and want to truly understand how to test all overcurrent relays from any manufacturer with any test-set.

    You will learn everything Chris Werstiuk knows about overcurrent relay testing over the following lessons:

    1. Introduction to Protective Relays
    2. How to Test Electro-Mechanical Overcurrent Relays
    3. Understanding Power System Faults
    4. How to Test Simple Digital Overcurrent Relays
    5. Introduction to the Power System Studies Used to Create Relay Settings
    6. How to Test Overcurrent Elements in IEDs

    This course is eligible for 32 NETA Continuing Technical Development Credits (CTDs). NETA Certified Technicians (Level III and Level IV) are required to earn a minimum of 48 CTDs every three years to maintain their certification. For more information about the CTD program and requirements, please contact the NETA office at neta@netaworld.org or 888-300-6382.

  • Fundamentals #4: How to Test Voltage Elements Inside IEDs/Relays (16 NETA CTDs)

    $399.95 Add to cart

    The How to Test Voltage Protection in IEDS/Relays Online Training Seminar is the last seminar in our Relay Testing Fundamentals Online Training program– which shows you how to connect, understand, and test Over- and Under-Voltage elements in IEDs/Relays with Wye, Open-Delta, and Broken Delta connections. This seminar also sets you up to test more advanced element tests with detailed information about three-phase, phase-to-phase, and phase-to-ground faults and symmetrical components.

    This new seminar has the following lessons:

    • Lesson 1: Introduction to Voltage Transformers (PTs or VTs)
    • Lesson 2: How to Test OverVoltage (59-Element) Protection Inside an IED/Relay
    • Lesson 3: Symmetrical Components for Relay Testers
    • Lesson 4: How to Test UnderVoltage Elements (27)
    • Lesson 5: How to Test IEDs/Relays With Delta PT Connections
    • Lesson 6: How to Test IEDs/Relays With Wye/Broken-Delta VT Connections
  • Fundamentals #3: How to Test Protective IEDs/Relays (16 NETA CTDs)

    $399.95 Add to cart

    This online protective relay testing seminar follows Chris Werstiuk (author of The Relay Testing Handbook) as he shows you the basic skills you need to test any digital relay with any modern test-set. Learn how to test protective relays with online videos that are broken down into logical chunks that you can watch at any time and in any order so that you can fit this series into your busy schedule.

    Sign up today and earn 16 NETA CTDs!