Online Course 1-2: Phasor Drawings for Relay Testers (4 NETA CTDs)

(22 customer reviews)

$49.95 USD

Waveform diagrams contain every detail of an electrical system, but that information can be difficult to understand without a lot of effort. Phasor drawings take the complex information embedded in waveform drawings and convert it into phasor diagrams so that you can see the most important information about an electrical system at a glance. Understanding phasor drawings is probably one of the most important skills that a relay tester must have to be successful!

Take this course to learn these topics:
Understanding Phasors and Creating Phasor Drawings

  • What Are Phasors?
  • How to Draw Phasor Diagrams
  • Drawing Phasors with Different Scales

Create and Understand Phasor Diagrams Used by Different Relay and Test-Set Manufacturers

  • Drawing Phasors with Lagging Angles (Megger and GE SR)
  • Draw Phasors with Positive Angles (Doble and Manta Test Systems)
  • Draw Phasors with Negative Angles (GE UR)
  • Draw Phasors with Positive and Negative Angles (Omicron and SEL)



Quantity discounts
1-5 $49.95 USD
6-10 $44.96 USD
11-20 $42.46 USD
21-50 $39.96 USD
51+ $34.97 USD
SKU: TRTH-OT1-2 Categories: , Tag:

Description

Phasor diagrams are your one-stop-shop for understanding an electrical system at a glance. You’d think that all of the relay test-sets, phase-angle meters, and relays would use the same angle systems to communicate this important information to prevent confusion. Unfortunately, you’d be wrong.

Imagine you’re testing an SEL relay using a Doble test-set and RTS software and you set up a simple three-phase, balanced, metering test (ABC). Each device would display the following angles during a typical meter test:

  1. A-Phase voltage = 0 degrees, B-Phase voltage = 120 degrees, C-Phase voltage = 240 degrees
  2. A-Phase voltage = 0 degrees, B-Phase voltage = -120 degrees, C-Phase voltage = 120 degrees
  3. A-Phase voltage = 0 degrees, B-Phase voltage = 240 degrees, C-Phase voltage = 120 degrees

Can you confidently match the angle system to the device? (Write down your answers and click to compare {RTS = ?, SEL = ?, Doble = ?})

RTS = 1, SEL = 2, Doble = 3

If you don’t know the difference between devices, you won’t be able to:

  • Perform a meter test properly (more on meter tests in the future)
  • Create effective test-plans
  • Troubleshoot test-plan problems

Can you believe that there is a fourth angle system out there we haven’t mentioned yet?

This course will introduce you to phasors and show you how to convert waveform drawings into phasor drawings so that you can understand what phasors are and how they are created.  You will be able to understand what is happening inside your relay and test-set with these topics:

  • What are Phasors?
  • How to Draw Phasor Diagrams
  • Drawing Phasors with Lagging Angles
  • Drawing Phasors with Different Scales

In a perfect world, these four lessons would be all you needed to become a phasor drawing master. You would be a master at understanding and drawing phasor diagrams in Megger test-sets and GE SR relays but, unfortunately, it seems every manufacturer has a different system for the angles in phasor drawings.  The remaining lessons in this course will help you understand all of the different angle systems used by test-sets from Doble, Omicron, and Manta Test Systems as well as the angle systems used by GE UR and SEL relays:

  • Draw Phasors with Positive Angles
  • Draw Phasors with Negative Angles
  • Draw Phasors with Positive and Negative Angles

You get immediate access to the course if you pay with a credit card. All of our online courses include:

  • High-quality video presentations introducing you to theory behind the topic to help you understand how it works
  • Real-world examples that show you how to apply the theory
  • Interactive exercises and quizzes that simulate the most realistic situations possible to help you learn by doing
  • A comment section where you can ask your questions and get your answers from instructors or fellow students

You can watch a 10-minute video below that will give you an introduction to the topics covered in this course.


Still not sure if this course is right for you? Test your knowledge with this quick quiz:

Test Your Knowledge

 

Sign-up today if you can’t answer all of the questions correctly,

This course is eligible for 4 NETA Continuing Technical Development Credits (CTDs). NETA Certified Technicians (Level III and Level IV) are required to earn a minimum of 48 CTDs every three years to maintain their certification. For more information about the CTD program and requirements, please contact the NETA office at [email protected] or 888-300-6382.

Do you want to enroll more than one person in our online training courses?  No problem!  Click the “Enable Group Registration” checkbox at the bottom of any course, then choose how many people you want to register before you click “Add to Cart”.  All bulk and coupon prices will still apply. You control who gets enrolled in the course via the “Group Registration” page. Enroll one at a time, or upload your entire team via a simple csv file. We’ll automatically create everything they need to start the course and send them an email with their username, password, and course links.

22 reviews for Online Course 1-2: Phasor Drawings for Relay Testers (4 NETA CTDs)

  1. Anonymous Student

    practicing always make you better having course material teaching you and showing you gives you a better understanding of what a phasor is

  2. Anonymous Student

    This course allows anyone with little or no knowledge to have an overview of how electrical devices works.

  3. Peter Cogswell, NETA III, NICET III

    The information in this course was very well presented. The practice sheets make the concepts more easily understood. I would recommend this course to anyone who is involved with Electrical Power Systems.

  4. Ahmad Shabazz

    Great fundamental courses, preparing you for any relay testing out there.

  5. Post-Course Evaluation Form Comments

    Very good explanations on phasors and testing.

  6. Customer Review Form

    Excellent for NETA CEU’s

  7. Student Review

    Great tool!

  8. Course Review

    This course is a must for anyone that is responsible for testing or maintaining Power Systems.

  9. Course Review

    You should take this course “to further their understanding of 3 phase phasors and vectors”

  10. Course Review

    It is something that is required for the Modern Test Engineer

  11. Customer Review

    If you are in relay P&C, you need this course for success in your field

  12. Customer Review

    Anyone who loves to be a relay engineer, Chris is the guy who can teach you so well, who can make you be what you wanted to be as a relay engineer.

    He is Second to none when it comes to teaching about relays. He is the Guru 🙂

  13. Rob P.

    In order to clarify already understood concepts and learn new ones in order to make themselves a more confident and reliable relay tester and commissioning tech. Also to be able to mentor in the correct manner to hopefully eliminate some of the so many bad habits of testers in the industry.

  14. customer review

    For people who feel they may know some details about relay testing but get confused by the different phase angles and phase rotation. It clears up the differences and opens your eyes to the need to be careful when trying to figure out phase rotation.

  15. A Relay Course Evaluation

    There isn’t a better, more thorough introduction to phasors that I’ve seen online.

  16. A Relay Course Evaluation

    This is one of the most helpful course for who is working on the field of switchgear and who willing to work on switchgear sector

  17. customer review

    How did the course help you?
    Totally understanding how to deal with the phasor diagrams which I do need to test and commission protection relays
    How do you feel about relay testing now?
    Much easier to test
    Why should someone take this course?
    It will help you to improve the testing skills much more than only practicing with no scientific knowledge

  18. A Relay Course Evaluation

    If you want to take your relay testing knowledge to the next level, this course is a must!

  19. A Relay Course Evaluation

    Excellent

  20. A Relay Course Evaluation

    If you don’t have any experience about relay testing, this will be little bit hard to understand. However, in my case, I just watched this course so many times before relay testing and now, I can go on right way to do it with confidence. This is really valuable for your carrier as relay tester.

  21. A Relay Course Evaluation

    How did you feel about testing relays before the course?
    I have never experienced before and just did bench top relay testing.
    How did the course help you?
    increase my knowledge regarding protection relay world and now I did my first job of SEL-700G for FAT testing.
    How do you feel about relay testing now?
    Very exciting and there are lots of fun and interests.
    Why should someone take this course?
    to verify their knowledge with other expert. since sometimes, they are very stubborn and tend to believe their experience.

  22. A Relay Course Evaluation

    I’ve done enough coursework in my life in various disciplines and trade crafts to have forgotten some of them. In all of my studies, I have rarely met an instructor who knew their material better, delivered it more clearly and effectively, or who obviously enjoyed teaching their subject more. His class helped me understand relay testing at a level far above what I knew before I took it. It would be difficult to overstate the value of his classes.

Add a review



Quantity discounts
1-5 $49.95 USD
6-10 $44.96 USD
11-20 $42.46 USD
21-50 $39.96 USD
51+ $34.97 USD

You may also like…

  • Sale!

    The Whole Enchilada

    $329.85 USD $299.95 USD



    Quantity discounts
    1-5 $299.95 USD
    6-10 $269.96 USD
    11-20 $254.96 USD
    21-50 $239.96 USD
    51+ $209.97 USD

    All the online theory and practical information we offer at once.

    Get instant access to everything:

    • Course 1-1: The Three-Phase Electric Power System (4 NETA CTDs)
    • Course 1-2: Phasor Drawings for Relay Testers (4 NETA CTDs)
    • Seminar 1: How to Test Protective Relays (16 NETA CTDs)
  • All Electrical Courses

    $79.90 USD



    Quantity discounts
    1-5 $79.90 USD
    6-10 $71.91 USD
    11-20 $67.92 USD
    21-50 $63.92 USD
    51+ $55.93 USD

    Take our online training courses to learn the basics all relay testers need

    Get instant access to:

    • The Three-Phase Electric Power System
    • Phasor Drawings for Relay Testers